RTCSmp

Built-In Module-Line Dual/Quad Cooktops

Part # 4532415 Rev 3 (8/19/14)

Page 15

4.2.2

Installation Clearance

a
Cable Bend /
Connection Clearance
(minimum)

b
Air Exhaust/
Intake Clearance
(minimum)

c
Clearance
(minimum)

Induction
Generator

127mm / 5”

40mm / 1.57”

10mm / 0.39”
(sides, top,
and bottom)

Control
Unit

70mm / 2.75”

--

38mm / 1.5”
(for service
interface)

Coil Carrier
Sheet

127mm / 5”

--

100mm /
3.94”
(below coil
carrier sheet)

Operation
Unit

12.7mm / 0.5“

--

--

4.3

Induction Generator

IMPORTANT

 The maximum operating temperature for the induction unit must not exceed 104F (40C).

 Buildup of hot exhaust air around the induction unit will cause the unit to reduce power or to switch-off.

Recommended: At an appropriate location on the cabinet, install an exhaust fan to force hot air out the

cabinet and away from the induction unit. Consult an electrical or installation expert for the most
appropriate location to install a cabinet exhaust fan.

Recommended: Filter the intake air with an air intake filter. Kitchen air often contains grease laden

vapors. Grease deposits inside the generator may cause overheating. Failure to provide clean fresh
cooling air may void warranty.

 NOTE: Additional fans and cooling controls are the responsibility of the customer and installer.

 Clearance: refer to the data in section 3.5 Operating Conditions.

a

c

b

b

c

c

c

c

a

a

a