Installation

RTCSmp

Built-In Module-Line Dual/Quad Cooktops

Part # 4532415 Rev 3 (8/19/14)

Page 25

4.5.5

Installation Steps

IMPORTANT

COUNTERTOP CUT-OUT DIMENSIONS, see section 4.5.4 Mounting Frames.

 When installing two coil carrier sheets on the same frame, you must install a non-magnetic steel

partition plate in between them. This will isolate the magnetic fields and prevent the fields from

interfering each other.

IMPORTANT

To protect the induction unit from water penetration, you must apply and bond the silicone adhesive
properly to create a water-tight seal. Before you begin the installation, it is very important to use isopropyl
alcohol (minimum 70%) or equivalent to clean the flanges/edges and the counter surfaces where the
silicone adhesive will be applied.

To install the mounting frame and Ceran glass:

A. Orientation: The mounting frame assembly has a set of retaining rails that are hinged at the BACK of the

frame. The rails can drop down at the FRONT for installing the coil carrier sheet. Ensure to install the
frame in the correct orientation according to the design/layout plan.

B. Secure the mounting frame to the underside of the counter surface. Stud-mounting method is shown in

illustration.

B

min 1.5 [0.06]

A

Advertising