1 location, 2 ventilation, 3 dimensions – Garland MO QU 28000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD User Manual

Page 16

Advertising
background image

Installation

RTCSmp

Built-In

Module-Line Dual/Quad Cooktops


16

Part # 4532415 Rev 3 (8/19/14)

4.3.1

Location

 It is possible to install the induction unit near heat-producing or steam-producing equipment such as an

oven or a fryer. However, use an external fan to pull hot air, greasy fume, and moisture away from the
induction unit.

 If the generator is installed directly under the induction coil or in the same chamber of as the coil, ensure

the ventilation system will keep the ambient temperature below 104

F (40C).

 Keep all combustible materials, vapors or liquids away from the generator.

 Ensure the installed location of the generator is safe from any ingress of liquid into the immediate

vicinity.

 The generator can be mounted in any orientation as long as:

o

the equipment and cable connections are accessible for maintenance and service.

o

the fresh air intake and exhaust air outlet are not blocked.

4.3.2

Ventilation

 Maximum air flow of the fan is 70.63 cfm (120 m

3

per hour) and therefore a minimum opening of 10.08

sq. in. (6500 mm

2

) is required around the fresh air intake.

 An optimal air circulation and air flow must not be restricted by installation.

 The in-take air and exhaust air must not mix. To avoid build-up of hot exhaust air inside the cabinet, use a

fan to draw the exhaust air out, or provide a separate exhaust air plenum.

4.3.3

Dimensions

Models: MO DU 7000/ 10000 MO QU14000/ 20000/ 21000/ 24000

23.62” (600 mm)

min 1.57” (40 mm)

min 5” (127mm)

23.62” (600 mm)

14.17”

(360 mm)

6.02” (153 mm)

2.58”

(65.5 mm)

6.81” (173 mm)

6.22”

(158 mm)

3.98”

(101 mm)

3.98”

(101 mm)

1.02”

(26 mm)

mains connection

CAN/BUS

air exhaust

clearance

air supply

coil

connection

field 1+2

air supply

air exhaust

1.57”

(40 mm)

fan

cable bend

clearance