Installation

RTCSmp

Built-In

Module-Line Dual/Quad Cooktops


28

Part # 4532415 Rev 3 (8/19/14)

4.5.6

Custom-Built Mounting Frame

Mounting Frame for countertop thickness of 1.5mm to 3mm / 16- to 10-gauge (Typ.): See section 4.5.4.

Mounting Frame for countertop thickness of 20-30mm/ 1”:

For an application with countertop thickness about 1” or 20 – 30 mm, a custom-built mounting frame is
required to flush-mount the glasstop and install the coil carrier sheet properly. When designing an
appropriate frame, use the design criteria and the example below as your guide.

NOTE: You may re-use existing parts from the mounting frame provided.

NOTE: Refer to section 4.5.4 and 4.5.5 for cut-out dimensions and recommended installation procedure.

NOTE: Please contact Garland if you would require assistance on designing a proper frame. CAD files for

the example shown in this section are available upon request.

Mounting Frame Design Criteria

 The coil carrier sheet(s) should be easily removable for service/maintenance without taking out the glass-

top.

 Height-adjustable feature for leveling the unit during installation is desirable.

 Use 10- to 14-gauge metal (typ. 12-gauge) for the mounting frame.

 When installing two coil carrier sheets on the same frame, you must install a non-magnetic steel

partition plate in between them. This will isolate the magnetic fields and prevent the fields from
interfering each other.

 The mounting frame has to support the total weight of the glass, the coil carrier sheet(s), the cookware,

and food product.

 Critical dimensions:

o

Countertop cut-out dimension, see section 4.5.4.

o

Distance from the underside of the coil carrier sheet to the Ceran glass after installation: 50mm

+/- 2mm.

o

Thickness of glass + silicone gasket + silicone seal = 6mm + 3mm + approx. 0.5mm = total

approx. 9.5mm. See section 4.5.5 steps C to F.