Installation

RTCSmp

Built-In Module-Line Dual/Quad Cooktops

Part # 4532415 Rev 3 (8/19/14)

Page 27

H. Guided by the retaining rails, carefully insert the back end of the coil carrier sheet into the frame. The coil

and sensor connectors should be facing the front. The retaining rails provide additional support to the
coil carrier sheet.

I.

While holding the coil carrier sheet together with the retaining rails, swing the rails back into the original
position and tighten the screws.

J. The coils and temperature sensors installed on the coil carrier sheet must exert a constant pressure of

5mm to the Ceran glass. This pressure ensures the temperature monitoring to work properly. Do not
allow any gap between the temperature sensors and the glass. You MUST set the pressure correctly.

To adjust the pressure correctly:

i. Bolts of the coil carrier sheet must protrude 5mm from the coil carrier sheet.

ii. Distance from the underside of the coil carrier sheet to the Ceran glass: 50mm +/- 2mm.

iii. When extra compression is required, install M4 screws (not provided) to the retaining rails. Tighten

or loosen the M4 screws to adjust to the correct pressure.

J

5mm

J

50.1mm
[1.97”]

i

ii

iii

J