background image

Condition Monitoring Unit CMU 1000

Page 15

Revised 17.12.2009

HYDAC ELECTRONIC GMBH Mat.-No.:

669749

Plugs Pin Channel

Function

I/O

1

CAN CAN Bus Low

IN / OUT

2

CAN CAN Bus High

IN / OUT

3

GND CAN GND

4

Q

Frequency input Q

IN

5

R

Frequency input R

IN

6

GND GND

7

DI 1 Digital In 1

IN

8

DI 2 Digital In 2

IN

9

GND GND

10

AO 1 Analoge out 1

OUT

11

AO 2 Analoge out 2

OUT

X4

12

GND GND Analoge out

1

HSI

HSI Master

IN / OUT

2

RS232 RS232 OUT

3

RS232 RS232 IN

4

IO-Link

Power supply IO-Link

IN

5

IO-Link

IO-Link communication

IN / OUT

6

GND GND HSI / RS232 / IO-Link

7

+U

B

Power supply +U

B

8

+U

B

Power supply +U

B

9

0 V DC Power supply 0 V DC

10

0 V DC Power supply 0 V DC

11

0 V DC Power supply 0 V DC

X5

12

0 V DC Power supply 0 V DC

1

Relay 1 NC

2

DO 1 Relay 1 COM

3

Relay 1 NO

4

Relay 2 NC

5

DO 2 Relay 2 COM

6

Relay 2 NO

7

Relay 3 NC

8

DO 3 Relay 3 COM

9

Relay 3 NO

10

Relay 4 NC

11

DO 4 Relay 4 COM

X6

12

Relay 4 NO