T3000 – INFICON T3000 Thermal Power Supply User Manual

Page 23

Advertising
background image

T3000

Thermal Power Supply

instruments

Section 3

Page 3 - 2

Section 3

personnel may request this information, when service calls are made to the factory.

Table 3.1-2 summarizes the different modes associated with the three LED’s.


Table 3.1-2

T3000 LED Mode Indication Summary

Start-up
Timing
Seconds

Power ON
Indicator
Green LED

Internal
Over
Temperature
Red LED

Open Load
Condition
Red LED



Condition

0 to 1

Steady Glow Steady Glow Steady Glow LED Checkout

1 to 9

Blink in sequence per
version code

Steady Glow Denotes Firmware Version

Blink
once/sec

Dark

Dark

Ready for output power
Enable

Steady Glow Dark

Dark

Output Power Enabled -
Operational

Blink
once/sec

Dark

Steady Glow Open Load; Output Power

Inhibited

Blink
once/sec

Steady Glow Dark

Over Temp; Output Power
Inhibited

After Start
Sequence is
completed

Blink
once/sec

Blinks
twice/sec

Dark

Cooled down; Ready for
reset



Figure 3.1-1 shows the location of the three LEDs and push-button reset switch on the rear panel of
the T3000.

Advertising