Introduction – Description
of Equipment

Page 1 - 2

Section 1

although it contains both DC and harmonics of line frequency. Therefore, the heating value
in the load (the resistive deposition source) is the same whether the current is sine wave,
rectified sine wave or a DC voltage all of equal RMS value.

The rectified line frequency was chosen as the output format because it offers an inherent
unity power factor characteristic for the power supply. This comes about because power is
being delivered to the resistive load throughout the 60-Hertz cycle of line frequency. Since
conversion from line to output is performed at 250 kHz, there is insignificant phase shift
introduced at the 60-Hertz line frequency. The net result is input line current that is, ideally,
sinusoidal and essentially in-phase with the line voltage. This is the condition for near unity
power factor.

1.3 Technical

Characteristics

Table 1-1

Specifications

Output Power

3000 Watts

Parallel Output

5 Volts @ 600 Amps RMS

Series Output

10 Volts @ 300 Amps RMS

Input Voltage Range

180-264 VAC, Single Phase

Input Freq. Range

47 Hz to 63 Hz

Input Current

18 Amps @ 220 VAC

Efficiency

80% Full Load

Power Factor

>0.99 @ Full Load

(TBD)

Total Harmonics

< 5% @ Full Load

(TBD)

Input Control

0 to +10VDC Required For Controlling Output Current

Response Time

<100ms 250A to 500A Step Parallel Output

1

Current Monitor

1 VDC = 100 Amps RMS For Parallel & 50 Amps For Series

Voltage Monitor

1 VDC = 1.5 Volt RMS Across Output Terminals

Protection

Over Temperature Shutdown

Size

11.4 in. H x 5.25 in. W x 12.9 in. D

Power Density

4 Watts per cubic inch

Weight 28

Pounds

Ambient Range

0

o

C to +50

o

C at full load

Cooling

Forced air, two internal fans

EMI

Designed to meet Conducted and Radiated EN55022

Safety

Designed to meet EN60950

Output Connectors

Flat bus bars with ¼” Bolt Hole for Lug Attachment

AC Input Wiring

2-Wire plus Ground with 8 – 32 lugs

I/O Connector

15-pin Dsub for control, monitoring and status signals

Power ON Indicator

Green LED: Flashing=Input Power ON, Steady=Output ON

Over Temperature

Red LED: Steady=Over Temp, Flashing=Ready for Reset

Open Load

Red LED: Steady=Open Load

Compatibility

Sycon Controller RS3000 &/or Rate Deposition Controllers

Footnote1; Response time is load dependent with lower resistance loads exhibiting faster response.