T3000, By stc, By rs3000 – INFICON T3000 Thermal Power Supply User Manual
Page 25
Advertising
T3000
Thermal Power Supply
instruments
Section 3
Page 3 - 4
Section 3
3.2 Basic
Operation
The T3000 can be used in several control configurations as depicted by the block diagrams of
Figure 3.2-1.
Pins 3 & 11
Pin 7
Pin 13
J1
OFF/ON
Vcontrol
0 - +10V
T3000
T3000
RS3000
Cable
T3000
STC
Custom Split Cable
T3000
RS3000
Cable
STC
Cable
To Multimeter Imon Pin 15
To Multimeter Vmon Pin 4
Ex ternal Fault Rest Pin 5
Momentary
PBS
To Multimeter Imon Pin 15
To Multimeter Vmon Pin 4
External Fault Rest Pin 5
Signal Ground Pins 3 & 11
For External Monitoring
J1
J1
J1
Figure 3.2-1 Various Methods For Controlling The T3000 Power Supply
CONTROLLED
BY STC
STAND ALONE
CONFIGURATION
CONTROLLED
BY RS3000
CONTROLLED BY
STC VIA RS3000
Advertising