Use of the T3000 with the
RS-3000

Page 4 - 6

Section 4

power supply output (in kilowatts.) The Kw indicator illuminates while the power value is
displayed, and the MIN indicator illuminates while the elapsed-time value is displayed.

The process may be stopped during Manual mode by pressing the STOP key.

Remote Mode: The Remote mode allows control of the power supply output via a remote
controller such as the Sycon Instruments STC-2000. See the RS-3000 manual for further
information.


4.4 Error

Conditions


The following messages and error indications may appear on the front panel of the RS-
3000:

Interlock” LED illuminated on front panel: This indicates that a problem exists with
the interlock system which must be resolved before the T3000 cam be operated.

Err” and “Opn” present on front panel displays: This indicates that an open boat
condition exists which must be resolved before the T3000 can be operated.

Err” and “Hot” present on front panel displays: This indicates that the T3000 power
supply has overheated, and must cool before it can be operated.

Err” and “PrG” present on front panel displays: This indicates a memory error,
which can be cleared by pressing the “PGRM” key.

MAX” LED indicator illuminated: This indicates that the output current has reached
the maximum value.