Hydraulic disc gang lift system, General operation – Landoll 2211 Ripoll User Manual

Page 62

Advertising
background image

4-6

F-571-0613 Edition

OPERATION AND MAINTENANCE

Hydraulic Disc Gang Lift System

The disc gang lift system must be purged of air before
beginning field operation.

1.

Make sure the tractor's hydraulic reservoir is full of
the manufacturer's recommended oil.

2.

Extend the lift cylinder and raise the machine.

3.

Fully extend and retract the disc gang cylinder to
allow oil to fill cylinder.

4.

Refill tractor hydraulic system.

IMPORTANT

Retracting the cylinders during periods of storage
will prevent rusting of shafts and subsequent
damage to seals.

General Operation

1.

The horsepower requirements are typically 20-25
horsepower per shank. This will vary widely due to
speed, depth, moisture, residue and types of soils.
Local dealers can help in making recommendations
for your areas.

2.

Operating speed is typically 4.5-6 mph. Excessive
speed can cause the unit to bounce, uneven depth,
and create undesirable ridges.

3.

Lift wheels must always be in contact with the ground
and carrying some implement weight. Lift wheels are
used to gauge the depth and to control the leveling
feature.

4.

Do not turn with the Ripoll in the ground. This can put
excessive side load on the gangs and hitch. Raise
the unit fully when making turns to prevent gouging
and pushing a ridge.