Safety engineering – Lenze i700 Manual User Manual
Page 134

Safety engineering
Technical data
l
134
EDS700ACBA EN 4.0
Safety−related parameters acc.to IEC 61508−1 to −7 and IEC 62061
Specification
Value
Comment
Safety Integrity Level
SIL 3
PFH [1/h]
7.79 E−10 0.78 % of SIL 3
PFD
6.82 E−5
6.8 % of SIL 3 after T = 20 years
Proof test interval
20 years
Mission time
Safety−related parameters acc. to EN ISO 13849−1
Specification
Value
Comment
Performance Level
e
Category
4
MTTF
d
high
71285 years
Diagnostic coverage DC
high
99 %
Note on safety−related parameters
Source of failure rates
SN 29500
As far as values from the
component manufacturers
were not available
Average max. ambient temperature
40 °C
General assumption that 50 % of the failures of
a component are hazardous failures
l
d
= 0.5
l, MTTFd = 2 MTTF
As far as other information was
not available