Technical data
Terminal description
Supply modules
l
48
EDS700ACBA EN 4.0
Connection of external brake resistor
X103
Labelling
Description
Rb1
Connection of brake resistor
Rb2
PE
Protective earth
+
i700PX103
Terminal data
Conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
flexible
0.5 ... 6
22 ... 10
0.5 ... 0.6
4.4 ... 5.3
4.5 x 0.8
Rb1
PE
Rb2
X103
"
"
|
+
i700S010 8
Fig. 4
Wiring of X103
X103
Connection of brake resistor
Rb1, Rb2
Brake resistor corresponding with rated data
"
Functional earth
", shield connection
The shielded cable for connection of a brake resistor is prepared in the same way as a motor
cable (
¶ 62). The free length of the cores for Rb1/Rb2 is to be 160 mm (PE: + 10 mm).