Technical data
Terminal description
Supply modules
l
47
EDS700ACBA EN 4.0
Connection to the DC bus (+U
G
, −U
G
)
X101/X102
Labelling
Description
UG+
DC−bus voltage UG+
UG−
DC−bus voltage UG−
Open the protection cover only if the device is deenergised!
To open the protection cover, press the lock between the clips of the
cover down using a screwdriver and swivel the protection cover
away from the device at the same time.
i700PX1012
Terminal data
Conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
Swivel hook
−
−
5.0
44.3
PH 3
X101
X102
Electrical data
UG+
UG−
Rated voltage
565/675 V
Current
Up to 40 °C: 100 A
40 ... 55 °C: −2.5 %/K
Polarity reversal
protection
For internal connection: not relevant