Technical data, Terminal description axis modules, Resolver – Lenze i700 Manual User Manual
Page 55
Advertising

Technical data
Terminal description
Axis modules
l
55
EDS700ACBA EN 4.0
Resolver
X7
Pin
Description
E70ACM...R
1
+REF
On single axis devices, this
connection is located on the
right−hand side below the labelling
"X7".
2
−REF
3
n. c.
4
+COS
5
−COS
6
+SIN
On double axis devices, there are two
of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.
7
−SIN
8
+KTY
9
−KTY
"
Shield connection at Sub−D housing
i700AX007 a b
X7
Electrical data
General
Cable length (system cable is recommended)
Max. 50 m
3
n. c.
1, 2
+REF, −REF
Input frequency
max. 250 kHz
4, 5
+COS, −COS
Excitation voltage
10 V
SS
6, 7
+SIN, −SIN
Carrier frequency
4 kHz, constant value
8, 9
+KTY, −KTY
Type
KTY 83−110