Technical data, Terminal description axis modules, Encoder – Lenze i700 Manual User Manual
Page 57

Technical data
Terminal description
Axis modules
l
57
EDS700ACBA EN 4.0
Encoder
X8
Pin
Description
EYF001... cable
1 V
SS
1 V
SS
Hiperface
X8
E70ACM...E
1
A
COS
On single axis devices, this
connection is located on the
right−hand side below the labelling
"X8".
2
GND
GND
3
B
Sin
4
V
CC
V
CC
5
Z
+RS485
6
n. c.
n. c.
7
−KTY
−KTY
8
n. c.
n. c.
B
A
X8
9
/A
Ref COS
On double axis devices, there are two
of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.
10
n. c.
n. c.
11
/B
Ref SIN
12
n. c.
n. c.
13
/Z
−RS485
14
+KTY
+KTY
15
n. c.
n. c.
i700AX007 a b
"
Shield connection at Sub−D housing
Electrical data
General
Cable length (system cable is recommended)
Max. 50 m
Encoder types
Sin/cos encoder, 1V
SS
Protocols
Hiperface®
Number of increments
1 ... 16383
Input frequency
max. 250 kHz
VCC
(GND)
Supply voltage
5 V ... 12 V
Current, max.
9 V
250 mA
12 V
+KTY, −KTY
Type
KTY 83−110