Technical data, Terminal description axis modules, Motor connection – Lenze i700 Manual User Manual
Page 62

Technical data
Terminal description
Axis modules
l
62
EDS700ACBA EN 4.0
Motor connection
X107/108
Labelling
Description
V
Motor phases
On double axis devices, there are
two of these connections.
Assignment of the axes:
l
Axis "A" = X108
l
Axis "B" = X107
V
W
PE
Motor earthing
+
"
Shield connection at the shield sheet
i700P00x
Terminal data
Conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
flexible
for the devices
E70ACMSx0054xx1xxx
E70ACMSx0104xx1xxx
E70ACMSx0204xx1xxx
E70ACMSx0054xx2xxx
E70ACMSx0104xx2xxx
E70ACMSx0204xx2xxx
E70ACMSx0324xx2xxx
0.2 ... 4
24 ... 12
0.5
4.4
3.5 x 0.6
flexible
for the devices
E70ACMSx0324xx1xxx
E70ACMSx0484xx1xxx
E70ACMSx0644xx1xxx
0.5 ... 16
22 ... 6
1.5
13.3
5.5 x 1
PE
W
V
U
+
"
X107
(B)
"
"
M
3~
+
X108
"
+
PE
W
V
U
(A)
"
"
M
3~
+
i700S010 9
Fig. 9
Wiring of X107 or X108
X107, X108
Connection of motor|s
A
1−axis module: axis A
B
Additionally for 2−axis module: axis B
"
Functional earth
", shield connection