Supply modules, Axis modules, Technical data – Lenze i700 Manual User Manual
Page 42: Overcurrent operation supply modules, 1 supply modules, 2 axis modules

Technical data
Overcurrent operation
Supply modules
l
42
EDS700ACBA EN 4.0
4.3.1
Supply modules
Power supply
modules
Short−time currents [A] acc. to cycle times
3 / 12 s
60 / 120 s
I
rdc
200%
I
max_3
75%
I
red_12
150%
I
max_60
75%
I
red_120
E70ACPSx0304x
30.0
60.0
19.8
45.0
22.5
E70ACPSx0604x
60.0
120
39.6
90.0
45.0
4.3.2
Axis modules
Axis modules
Short−time currents [A] at switching frequency of 4 kHz acc. to cycle times
3 / 12 s
60 / 120 s
I
r4
200%
I
max4_3
75%
I
red4_12
150%
I
max4_60
75%
I
red4_120
E70ACMSx0054xx1xxx
2.5
5.0
1.7
3.8
1.9
E70ACMSx0104xx1xxx
5.0
10.0
3.3
7.5
3.8
E70ACMSx0204xx1xxx
10.0
20.0
6.7
15.0
7.5
E70ACMSx0324xx1xxx
16.0
32.0
10.7
24.0
12.0
E70ACMSx0484xx1xxx
24.0
48.0
16.0
36.0
18.0
E70ACMSx0644xx1xxx
32.0
64.0
21.3
48.0
24.0
E70ACMSx0054xx2xxx
2 * 2.5
2 * 5.0
2 * 1.7
2 * 3.8
2 * 1.9
E70ACMSx0104xx2xxx
2 * 5.0
2 * 10.0
2 * 3.3
2 * 7.5
2 * 3.8
E70ACMSx0204xx2xxx
2 * 10.0
2 * 20.0
2 * 6.7
2 * 15.0
2 * 7.5
E70ACMSx0324xx2xxx
2 * 16.0
2 * 32.0
2 * 10.7
2 * 24.0
2 * 12.0