Technical data, Rated data axis modules, 480 v – Lenze i700 Manual User Manual

Page 38

Advertising
background image

Technical data

Rated data
Axis modules

4

l

38

EDS700ACBA EN 4.0

Switching frequency−dependent output currents

400 V

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

E70ACMSx0054xx1xxx

−

−

2.5

5.0

2.5

−

1.5

E70ACMSx0104xx1xxx

−

−

5.0

10.0

5.0

−

3.0

E70ACMSx0204xx1xxx

−

−

10.0

20.0

10.0

−

6.0

E70ACMSx0324xx1xxx

1)

−

−

16.0

32.0

12.8

−

9.6

E70ACMSx0484xx1xxx

1)

−

−

24.0

48.0

19.2

−

14.4

E70ACMSx0644xx1xxx

1)

−

−

32.0

64.0

25.6

−

19.2

E70ACMSx0054xx2xxx

−

−

2 * 2.5

2 * 5.0

2 * 2.5

−

2 * 1.5

E70ACMSx0104xx2xxx

−

−

2 * 5.0

2 * 10.0

2 * 5.0

−

2 * 3.0

E70ACMSx0204xx2xxx

−

−

2 * 10.0

2 * 20.0

2 * 10.0

−

2 * 6.0

E70ACMSx0324xx2xxx

1)

−

−

2 * 16.0

2 * 32.0

2 * 12.8

−

2 * 9.6

480 V

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

E70ACMSx0054xx1xxx

−

−

2.5

5.0

2.5

−

1.5

E70ACMSx0104xx1xxx

−

−

5.0

10.0

5.0

−

2.4

E70ACMSx0204xx1xxx

−

−

10.0

20.0

10

−

4.8

E70ACMSx0324xx1xxx

1)

−

−

16.0

32.0

12.8

−

7.7

E70ACMSx0484xx1xxx

1)

−

−

24.0

48.0

19.2

−

11.5

E70ACMSx0644xx1xxx

1)

−

−

32.0

64.0

25.6

−

15.4

E70ACMSx0054xx2xxx

−

−

2 * 2.5

2 * 5.0

2 * 2.5

−

2 * 1.5

E70ACMSx0104xx2xxx

−

−

2 * 5.0

2 * 10.0

2 * 5.0

−

2 * 2.4

E70ACMSx0204xx2xxx

−

−

2 * 10.0

2 * 20.0

2 * 10.0

−

2 * 4.8

E70ACMSx0324xx2xxx

1)

−

−

2 * 16.0

2 * 32.0

2 * 12.8

−

2 * 7.7

I

aNx

Rated value of continuous output current

bold

Nominal value I

aN

I

aMx

Maximum output current (overload current,

^ 40)

l

dynamic load change cycle of 3 s with I

aM4

and recovery time of 12 s with

75 % I

aN4

1)

Restriction for output frequencies 0 ... 5 Hz

l

dynamic load change cycle of 0.5 s with I

aM4

and recovery time of 2 s with

75 % I

aN4

If the output currents specified for a switching frequency of 16 kHz and 8 kHz are exceeded, the
switching frequency is automatically reduced to the next lower switching frequency.

Advertising