12

Lenze 13466185 EDBSW03 v5

Commissioning

4

Commissioning

4.1

Parameter setting

V0003

NOTE

If the password function is enabled, the password must be entered into C00 to

access the parameters. C00 will not appear unless the password function is enabled.

See C94.

4.2

Electronic programming module (EPM)

The EPM contains the controller’s memory. Whenever parameter settings are

changed, the values are stored in the EPM. It can be removed, but must be installed

for the controller to operate (a missing EPM will trigger an F1 fault). The controller

ships with protective tape over the EPM that can be removed after installation.

An optional EPM Programmer (EEPM1RA) is available that allows: the controller to be programmed

without power; OEM settings to be default settings; fast copying of EPMs when multiple controllers

require identical settings. It can also store up to 60 custom parameter files for even faster controller
programming

Status/fault messages

Change parameters

Tmd007