Commissioning – Lenze SMD 0-25kW-4-0kW Basic I/O User Manual

Page 22

Advertising
background image

20

Lenze 13466185 EDBSW03 v5

Commissioning

(1)

These parameters take effect only after power-up, h58 reset, “NMT reset node”, or “NMT reset communication services”

Code

Possible Settings

IMPORTANT

No.

Name

Lenze

Selection

h66

(1)

RPDO#1 mapping

(see RPDO

mapping details)

0

0 C0135 control word + C46 signed

C46 scaling: + 50 = + 1.0 Hz

1 C0135 control word + C46

unsigned

C46 scaling: 10 = 1.0 Hz

2 402 Drives and Motion Control:

PDO Controlword 0x6040

3 402 Drives and Motion Control:

PDO Controlword 0x6040 +

vl target velocity 0x6042

vl target velocity units = signed RPM

RPM calculation based on C87 and

C89

4 C0135 Controlword +

C46 signed and scaled +

Digital output

C46 scaling: +/- 16384 = C11

h69

RPDO#1 status

0 255

Read-only

Number of received RPDO#1

messages

Above 255, starts over at 0

RPDO#2 configuration parameters

h70

(1)

RPDO#2 COB ID

769 0 2047 If h53 = 0, 2: Setting will change to 768

+ Node ID during power-up or h58 reset.

h71

(1)

RPDO#2 enable/

disable

0

0 Disable
1 Enable

h72

RPDO#2

transmission type

255 0 255

h72 = 0...240: transfer on every

SYNC received

h72 = 254, 255: immediate transfer

h74

RPDO#2 event

monitoring timer

0

0

{ms}

65535 h74 = 0: monitoring disabled

h75

RPDO#2 time out

reaction

0

0 Not active

Only active when C01 = 3

1 Inhibit
2 Quick stop
3 Trip fault FC3

h76

(1)

RPDO#2 mapping

(see RPDO

mapping details)

0

0 C0135 control word + C46 signed

C46 scaling: + 50 = + 1.0 Hz

1 C0135 control word + C46

unsigned

C46 scaling: 10 = 1.0 Hz

2 402 Drives and Motion Control:

PDO Controlword 0x6040

3 402 Drives and Motion Control:

PDO Controlword 0x6040 +

vl target velocity 0x6042

vl target velocity units = signed RPM

RPM calculation based on C87 and

C89

4 C0135 Controlword +

C46 signed and scaled +

Digital output

C46 scaling: +/- 16384 = C11

h79

RPDO#2 status

0 255

Read-only

Number of received RPDO#2

messages

Above 255, starts over at 0