Commissioning – Lenze SMD 0-25kW-4-0kW Basic I/O User Manual

Page 21

Advertising
background image

Lenze 13466185 EDBSW03 v5

19

Commissioning

(1)

These parameters take effect only after power-up, h58 reset, “NMT reset node”, or “NMT reset communication services”

Code

Possible Settings

IMPORTANT

No.

Name

Lenze

Selection

h53

(1)

Parameter channel

2

(SDO#2 support for

Lenze Systembus)

0

0 Enable: Node ID range (1...63)

with default COB ID for SYNC,

RPDO and TPDO

h53 = 0, 1: CAN address 1...63; used

for SDO1. 64...127 used for SDO2.

SDO#1 COB ID = 1536 + Node ID

SDO#2 COB ID = 1600 + Node ID (if

enabled)

1 Enable: Node ID range (1...63)

with programmable COB ID using

h54, h60, h70, h80, h90

2 Disable: Node ID range (1...127)

with default COB ID for SYNC,

RPDO, and TPDO

3 Disable: Node ID range (1...127)

with programmable COB ID using

h54, h60, h70, h80, h90

h54

(1)

SYNC COB ID

128 0 2047 Note: Controller does not generate

SYNC object

h55

(1)

Boot up time

3000 0

{ms}

65535 Controller sends “NMT start all nodes”

message after this delay (active only

when h52 = 2)

h56

Heartbeat time

2000 0

{ms}

65535

Producer heartbeat time

h56 = 0 disables heartbeat

transmission

h58

Reset CAN node

0

0 No action

On transition from 0 to 1, re-initializes

CAN controller and activates changes

made to parameters marked with

(1)

1 Reset CAN communication

WARNING!

CAN re-initialization may activate new RPDO configurations, which can result in

changes to present controller state, including starting.

h59

CANopen status

0 Not initialized

Read-only

Note: RPDOs and TPDOs are only

active in operational state (h59 = 5)

1 Initializing
2 Stopped
3 Pre-operational
4 reserved
5 Operational

RPDO#1 configuration parameters

h60

(1)

RPDO#1 COB ID

513 0 2047 If h53 = 0, 2: Setting will change to 512

+ Node ID during power-up or h58 reset.

h61

(1)

RPDO#1 enable/

disable

1

0 Disable
1 Enable

h62

RPDO#1

transmission type

255 0 255

h62 = 0...240: transfer on every

SYNC received.

h62 = 254, 255: immediate transfer

h64

RPDO#1 event

monitoring timer

0

0

{ms}

65535 h64 = 0: monitoring disabled

h65

RPDO#1 time out

reaction

0

0 Not active

Only active when C01 = 3

1 Inhibit
2 Quick stop
3 Trip fault FC3

Advertising
This manual is related to the following products: