3.2.4 Control terminals

NOTE

LOW = 0 to +3V, HIGH = +12 to +30V.

Protection against contact

• All terminals have basic isolation (single insulating distance)

• Protection against contact can only be ensured by additional measures (i.e. double insulation)

STOP!

In the case of a Spinning Motor:

To bring free-wheeling loads such as fans to a rest before starting the drive, use the DC

injection braking function (“Auto-DCB”). Starting a drive into a freewheeling motor creates

a direct short-circuit and may result in damage to the drive.
Confirm motor suitability for use with DC injection braking.

Terminal

Data for control connections

(printed in bold = Lenze setting)

7

Reference potential

8

Analog input

0 … 10 V

(changeable under C34)

input resistance: >50 kΩ

(with current signal: 250 Ω)

9

Internal DC supply for setpoint potentiometer

+10 V, max. 10 mA

20

Internal DC supply for digital inputs

+12 V, max. 20 mA

28

Digital input Start/Stop

LOW = Stop

HIGH = Run Enable

R

i

= 3.3 k

E1

Digital input configurable with CE1

Activate fixed setpoint 1 (JOG1)

HIGH = JOG1 active

E2

Digital input configurable with CE2

Direction of rotation

LOW = CW rotation

HIGH = CCW rotation

E3

Digital input configurable with CE3

Activate DC injection brake (DCB)

HIGH = DCB active

K12

Relay output (normally-open contact)

configurable with C08

Fault (TRIP)

AC 250 V / 3 A

DC 24 V / 2 A … 240 V / 0.22 A

K14