Parameter data transfer

PROFIdrive parameter data channel

PROFIdrive DP−V1

8

l

105

EDSMF2133IB EN 5.0

Parameter format

Byte 11

Byte 12

U8

Format

U8

Number of values

Format: 0x01 ... 0x36, data types

0x41, byte
0x42, word
0x43, double word

Number of values: 0x01 or

number of subindexes requested

l

If there is more than one subindex, only the parameter value is
repeated.

Parameter value

Depending on the data type, the user data are assigned as follows:

Data type

Length

Assignment of the user data

Byte 13

Byte 14

Byte 15

Byte 16

Byte ...

String

x bytes

U8

1 byte

00

High byte

Low byte

U16

2 bytes

High word

Low word

High byte

Low byte

High byte

Low byte

U32

4 bytes

(This representation applies to one parameter value.)

8.3.1.8

Response to a correctly executed write request

Response header

Byte 1

Byte 2

Byte 3

Byte 4

U8

Request reference

(mirrored)

U8

Response identification

U8

Axis

(mirrored)

U8

Number of indexes

Request reference: Mirrored value of parameter request

Response identification: 0x02 (parameter has been written)

Axis: 0x00 or 0x01

Number of indexes: 0x"n" (number of parameters requested)