4 axis modules ecsxs / ecsxa, Axis modules ecsxs / ecsxa, Commissioning – Lenze EMF2133IB User Manual

Page 41

Advertising
background image

Commissioning

Preparing the standard device for communication

Axis modules ECSxS / ECSxA

6

l

41

EDSMF2133IB EN 5.0

6.6.4

Axis modules ECSxS / ECSxA

Step

Procedure

Detailed
information

1.

ECSxS

Set the Lenze parameter "Control mode":

l

C3005 = 1003 (setpoint via AIF, speed−controlled)

l

C3005 = 4003 (setpoint via AIF, torque−controlled)

Example of PROFIBUS Write:

l

C3005=1003 (speed control)

l

Index = 0x5442 (resulting from 0x5FFF − C3005

hex

)

l

Subindex: 0

l

Value: 10030000 (resulting from 1003 x 10

4

)

^ 46

Documentation of
the standard device

ECSxA

Implement the system blocks AIF−IN1 ... 3, AIF−OUT1 ... 3 and, if
available, the AIF management into the control configuration of the
IEC61131 project.

2.

The terminals SI1 (controller enable) and SI2 (pulse inhibit) are always active
and must be assigned to HIGH level during PROFIBUS operation. Otherwise
the controller cannot be enabled by PROFIBUS.

3.

The controller can now accept control and parameter setting data via the
PROFIBUS.

)

Note!

ECS servo system
ECS devices cannot be used with the DRIVECOM or PROFIdrive control.