Electrical installation 4 – Lenze E82ZAFVC001_ User Manual

Page 43

Advertising
background image

Electrical installation

4

EDK82ZAFVC001 DE/EN/FR 2.0

43

l

M5 Kabelspezifikation−innenschaltung

Features of the data line

Insulation diameter

1.96 mm (nominal)

Conductor pair

Copper 24 min.; min. 19 cores (individually tinned)

Colours

Light−blue, white

Pair twist / m

Approx. 16

Tape shield over conductor pair

1000/1000, Al/Mylar, Al side out, w−shorting fold (pull−on applied)

Impedance

120 Ohm +/− 10% (at 1 MHz)

Propagation delay

4.46 ns/m (max.)

Capacitance between conductors

39.37 pF / m at 1 kHz (nominal)

Capacitance between a condcutor and the
conductor connected to the shield

78.74 pF / m at 1 kHz (nominal)

Capacitive unbalance

3.94 pF/1000 m at 1 kHz (max.)

Spec. DC resistor at 20°C

91.86 Ohm/1000 m (max.)

Attenuation

0.95 dB/100 m at 125 kHz (max.)
1.64 dB/100 m at 500 kHz (max.)
2.30 dB/100 m at 1.00MHz (max.)

Features of the voltage line

Conductor pair

Copper 22 min.; min. 19 cores (individually tinned)

Insulation diameter

1.4 mm (nominal)

Colours

Red, black

Pair twist / m

Approx. 16

Tape shield over conductor pair

1000/1000, Al/Mylar, Al side out, w−shorting fold (pull−on applied)

Spec. DC resistor at 20°C

57.41 Ohm/1000 m (max.)