6 technical data, General data and operating conditions, Technical data – Lenze E82ZAFVC001_ User Manual
Page 57
Technical data
General data and operating conditions
6
EDK82ZAFVC001 DE/EN/FR 2.0
57
l
H1_Daten−E82ZAFVC001 − bemessDat
6
Technical data
General data and operating conditions
Field
Values
Communication profile
DeviceNet
Communication medium
DIN ISO 11898
Network topology
Line terminated at both ends (R = 120 Ohms)
Max. number of devices
63
DeviceNet device
Slave
Baud rate [kbit/s]
125, 250, 500
Achievable bus cable length
Depending on the cable used, see
^ 48
External voltage supply
See
^ 44
Ambient conditions
Climatic conditions
Storage 1 K3 acc. to IEC/EN 60721−3−1
− 25 ... + 60 °C
Transport 2 K3 acc. to IEC/EN 60721−3−2
− 25 ... + 70 °C
Operation 3 K3 acc. to IEC/EN 60721−3−3
− 20 ... + 60 °C
Degree of pollution
2 acc. to IEC/EN 61800−5−1
Enclosure
IP20
Connections
X3/
V+
External DC voltage supply of the function module:
+24 V DC ±10 %, max. 80 mA
The current flowing via terminal V+ during looping through of
the supply voltage to other devices, is to amount to a
maximum of 3 A.
7
Reference potential 1
39
Reference potential 2 of the controller inhibit (CINH) at X3/28
28
Controller inhibit
l
Start = HIGH (+12 V ... +30 V)
l
Stop = LOW (0 V ... +3 V)
Input resistance: 3.3
k
W
20
+ 20 V internal for CINH, reference potential 1, load capacity:
I
max
= 30 mA