6 technical data, General data and operating conditions, Technical data – Lenze E82ZAFVC001_ User Manual

Page 57

Advertising
background image

Technical data

General data and operating conditions

6

EDK82ZAFVC001 DE/EN/FR 2.0

57

l

H1_Daten−E82ZAFVC001 − bemessDat

6

Technical data

General data and operating conditions

Field

Values

Communication profile

DeviceNet

Communication medium

DIN ISO 11898

Network topology

Line terminated at both ends (R = 120 Ohms)

Max. number of devices

63

DeviceNet device

Slave

Baud rate [kbit/s]

125, 250, 500

Achievable bus cable length

Depending on the cable used, see

^ 48

External voltage supply

See

^ 44

Ambient conditions

Climatic conditions

Storage 1 K3 acc. to IEC/EN 60721−3−1

− 25 ... + 60 °C

Transport 2 K3 acc. to IEC/EN 60721−3−2

− 25 ... + 70 °C

Operation 3 K3 acc. to IEC/EN 60721−3−3

− 20 ... + 60 °C

Degree of pollution

2 acc. to IEC/EN 61800−5−1

Enclosure

IP20

Connections

X3/

V+

External DC voltage supply of the function module:
+24 V DC ±10 %, max. 80 mA

The current flowing via terminal V+ during looping through of
the supply voltage to other devices, is to amount to a
maximum of 3 A.

7

Reference potential 1

39

Reference potential 2 of the controller inhibit (CINH) at X3/28

28

Controller inhibit

l

Start = HIGH (+12 V ... +30 V)

l

Stop = LOW (0 V ... +3 V)

Input resistance: 3.3

k

W

20

+ 20 V internal for CINH, reference potential 1, load capacity:
I

max

= 30 mA

Advertising