Indexer-Programmer-Manual.pdf REV 1.3


Here is an example:
;
;This program handles faults correctly
;
UNITS=1
.
.
.

{Some initialization code}

.


PROGRAM_START:
ENABLE

MOVED 10
MOVED -10
.
. {Program

statements}

.

END
;----------------------------------------------------------------------------
----------
;Fault Handler. If any fault occurs following program will run:
;----------------------------------------------------------------------------
-- -------
ON FAULT ;statement starts fault handler

.
;Fault handler program. Motion stopped, Drive disabled, events not scanned
;while executing fault handler statements
;
;Do whatever necessary in your system
;after fault is detected. Turn ON/OFF some outputs …etc.
.
. {Statements}
.

RESUME PROGRAM_START

;program restarts from label PROGRAM_START

;

RESET

;you can use this statement instead.

;to start program from the beginning


ENDFAULT

;fault handler MUST end with this statement