Reference – Lenze PM94P01C User Manual

Page 107

Advertising
background image

PM94P01C

105

Reference

Index Name

Type Format EPM Access Description

Units

29

VAR_ENABLE_SWITCH_TYPE

W

Y

R/W

Enable switch function
0 - inhibit only
1 - Run

Bit

30

VAR_CURRENTLIMIT

F

Y

R/W Current limit

[A]mp

31

VAR_PEAKCURRENTLIMIT16

F

Y

R/W Peak current limit for 16kHz operation

[A]mp

32

VAR_PEAKCURRENTLIMIT

F

Y

R/W Peak current limit for 8kHz operation

[A]mp

33

VAR_PWMFREQUENCY

W

Y

R/W

PWM frequency selection
0 - 16kHz
1 - 8kHz

34

VAR_DRIVEMODE

W

Y

R/W

Drive mode:
0 - torque
1 - velocity
2 - position

WARNING! You can

change operating modes
when required during program
execution but do

not change

modes on the fly (with drive
enabled), as this may cause
unexpected behavior of the
motor.

35

VAR_CURRENT_SCALE

F

Y

R/W

Analog input #1 current reference scale
Range: Model dependent

A/V

36

VAR_VELOCITY_SCALE

vel

F

Y

R/W

Analog input #1 velocity reference scale
Range: -10,000 to +10,000

RPM/V

37

VAR_REFERENCE

W

Y

R/W

Reference selection:
1 - internal source
0 - external

38

VAR_STEPINPUTTYPE

W

Y

R/W

Selects how position reference inputs
operating:
0 - Quadrature inputs (A/B)
1 - Step & Direction

39

VAR_MOTORTHERMALPROTECT

W

Y

R/W

Motor thermal protection function:
0 - disabled
1 - enabled

40

VAR_MOTORPTCRESISTANCE

F

Y

R/W

Motor thermal protection PTC cut-off
resistance in Ohms

[Ohm]

41

VAR_SECONDENCODER

W

Y

R/W

Second encoder:
0 - Disabled
1 - Enabled

42

VAR_REGENDUTY

W

Y

R/W

Regen circuit PWM duty cycle in %
Range: 1-100%

%

43

VAR_ENCODERREPEATSRC

W

Y

R/W

Selects source for repeat buffers:
0 - Model 940 - Encoder Port P4
0 - Model 941 - 2nd Encoder Option Bay
1 - Model 940 - 2nd Encoder Option Bay
1 - Model 941 - Resolver Port P4

44

VAR_VP_GAIN
Short Name: VGAIN P

vel

W

Y

R/W

Velocity loop Proportional gain
Range: 0 - 32767

45

VAR_VI_GAIN
Short Name: VGAIN I

vel

W

Y

R/W

Velocity loop Integral gain
Range: 0 - 32767

46

VAR_PP_GAIN
Short Name: PGAIN_P

W

Y

R/W

Position loop Proportional gain
Range: 0 - 32767

47

VAR_PI_GAIN
Short Name: PGAIN_I

W

Y

R/W

Position loop Integral gain
Range: 0 - 16383

48

VAR_PD_GAIN
Short Name: PGAIN D

W

Y

R/W

Position loop Differential gain
Range: 0 - 32767

Advertising