3 quick start examples, 1 quick start - external torque/velocity, Reference – Lenze PM94P01C User Manual

Page 119

Advertising
background image

PM94P01C

117

Reference

3.3

Quick Start Examples

Contained in the following four paragraphs are the connections and parameter settings to quickly setup a PositionServo
drive for External Torque/Velocity, External Positioning, Internal Torque/Velocity and Internal Positioning modes. These
Quick Start reference tables are NOT a substitute for reading the PositionServo User Manual. Observe all safety notices
in the PositionServo User and Programming Manuals.

3.3.1 Quick Start - External Torque/Velocity

Table 63: Connections for External Torque/Velocity Mode

I/O (P3)

Pin

Name

Function

20

AIN2+

Positive (+) of Analog signal input

21

AIN2-

Negative (-) of Analog signal input

22

ACOM

Analog common

23

AO1

Analog output

24

AIN1+

Positive (+) of Analog signal input

25

AIN1 -

Negative (-) of Analog signal input

26

IN_A_COM

Digital input group A COM terminal

27

IN_A1

Digital input A1

28

IN_A2

Digital input A2

29

IN_A3

Digital input A3

30

IN_A4

Digital input A4

31

IN_B_COM

Digital input group B COM terminal

32

IN_B1

Digital input B1

33

IN_B2

Digital input B2

34

IN_B3

Digital input B3

35

IN_B4

Digital input B4

36

IN_C_COM

Digital input group C COM terminal

37

IN_C1

Digital input C1

38

IN_C2

Digital input C2

39

IN_C3

Digital input C3

40

IN_C4

Digital input C4

41

RDY+

Ready output Collector

42

RDY-

Ready output Emitter

43

OUT1-C

Programmable output #1 Collector

44

OUT1-E

Programmable output #1 Emitter

45

OUT2-C

Programmable output #2 Collector

46

OUT2-E

Programmable output #2 Emitter

47

OUT3-C

Programmable output #3 Collector

48

OUT3-E

Programmable output #3 Emitter

49

OUT4-C

Programmable output #4 Collector

50

OUT4-E

Programmable output #4 Emitter

Note 1: Connections

highlighted in BLUE

are mandatory/necessary for operation in this mode.

Advertising