Installation, 2 emi protection, 3 enclosure – Lenze S94P01G Position Servo User Manual

Page 18

Advertising
background image

S94P01G

16

Installation

EMC

Compliance with EN 61800-3:2004
In a domestic environment this product may cause radio interference. The user may
be required to take adequate measures
Noise emission

Drive Models ending in the suffix “2F” are in
compliance with class A limits according to
EN 55011 if installed in a control cabinet and
the motor cable length does not exceed 10m.
Models ending in “N” will require an appropriate
line filter.

Installation according to EMC
Requirements

E

D

B

C

A

F

S930

A Screen clamps

B Control cable

C Low-capacitance motor cable

(core/core < 75 pF/m, core/screen < 150 pF/m)

D Earth grounded conductive mounting plate

E Encoder Feedback Cable

F Footprint or Sidemount Filter (optional)

3.2.2 EMI Protection

Electromagnetic interference (EMI) is an important concern for users of digital
servo control systems. EMI will cause control systems to behave in unexpected and
sometimes dangerous ways. Therefore, reducing EMI is of primary concern not only
for servo control manufacturers such as Lenze, but the user as well. Proper shielding,
grounding and installation practices are critical to EMI reduction.

3.2.3 Enclosure

The panel in which the PositionServo is mounted must be made of metal, and must be
grounded using the SPG method outlined in section 3.2.1.

Proper wire routing inside the panel is critical; power and logic leads must be routed in
different avenues inside the panel.

You must ensure that the panel contains sufficient clearance around the drive. Refer to
section 2.9 for the recommended cooling air clearance.

Advertising