The number entered into this field, 0-15, directly correlates to a different encoder
resolution. Please reference the table herein.

Resolver Track Configuration

Resolver

Track

Resolution

Before Quad

Resolver Track

Resolution

Before Quad

0

1024

8

1000

1

256

9

1024

2

360

10

2000

3

400

11

2048

4

500

12

2500

5

512

13

2880

6

720

14

250

7

800

15

4096

5.3.23 Current Limit Max Overwrite

If this parameter is set to “Disable”, the parameters “Current limit”, “8 kHz peak current
limit” and “16 kHz peak current limit” cannot be overwritten. If you want to overwrite
the above three current limit parameters, this parameter must be set as “Enable”. To
prevent the motor from overloading, the “current Limit”, “8 kHz peak current limit” and
“16 kHz peak current limit” shall be set to values no higher than the corresponding
current limits of the motor in use. Note that this parameter applies to firmware version
(3.06) or higher.

5.4

Communication

5.4.1 Ethernet Interface

Programming and diagnostics of the PositionServo drive are done over the standard
10/100 Mbps Ethernet communication port. All devices on an Ethernet network have an
IP address. Before connecting MotionView software to the PositionServo drive, set up
the IP address of the drive and configure the PC as well.

The IP address of the PositionServo drive is composed of four sub-octets that are
separated by three dots. This conforms to the Class C Subnet structure. The sub-octets
IP_1, IP_2, IP_3 and IP_4 can be found by using “UP” and “DOWN” buttons of the LED
panel and are organized in the following order:

IP_1.IP_2.IP_3.IP_4

where each sub-octet IP_x can be any number between 1-254. On the LED display,
only IP_4 can be changed. IP_1, IP_2 and IP_3 can be changed once the PositionServo
drive is connected to the MotionView software. As shipped from the factory the default
IP address is 192.168.124.120.

If using the default PC Ethernet port on your computer for internal use (email, web
browsing, etc,) AC Tech recommends that you add an additional Ethernet port to
your PC. The most common and cost effective way to do this is by using a USB /
Ethernet dongle or a PCMCIA Ethernet card. Then configure this Ethernet port to the
PositionServo Subnet address and leave your local connection for your internal use.

There are two modes to obtain the IP address of the PositionServo drive by setting
DHCP equal to either 0 or 1. These modes are described herein. It is important to know
that the drive must be rebooted after changing any Ethernet settings such as IP address
and DHCP.