Diagnostics 8.2 leds, 3 faults, 1 fault codes – Lenze S94P01G Position Servo User Manual

Page 76

Advertising
background image

S94P01G

74

Diagnostics

8.2

LEDs

The PositionServo has five diagnostic LEDs located around the periphery of the front
panel display as shown in the drawing below. These LEDs are designed to help monitor
system status and activity as well as troubleshoot any faults.

S913

LED

Function

Description

A

Enable

Orange LED indicates that the drive is ENABLED (running).

B

Regen

Yellow LED indicates the drive is in regeneration mode.

C

Data Entry

Yellow LED will flash when changing.

D

Comm Fault

Red LED illuminates upon a communication fault. (in CANbus only)

E

Comm Activity

Green LED flashes to indicate communication activity.

8.3

Faults

8.3.1 Fault Codes

Listen herein are fault codes caused mostly by hardware operations. Refer to the
PositionServo Programming Manual for additional fault codes related to programming.

Fault

Code

(Display)

Fault

Description

F_OU

Over voltage

Drive bus voltage reached the maximum level, typically due to motor
regeneration

F_FB

Feedback error

Invalid Hall sensors code; Resolver signal lost or at least one motor hall
sensor is inoperable or not connected.

F_OC

Over current

Drive exceeded peak current limit. Software incapable of regulating current
within 15% for more than 20mS. Usually results in wrong motor data or
poor tuning.

F_Ot

Over temperature

Drive heatsink temperature has reached maximum rating.
Trip Point = 100°C for all drives except 480V 6A & 9A drives
Trip Point = 108°C for 480V 6A & 9A drives

F_OS

Over speed

Motor has reached velocity above its specified limit

F_PE

Position Error

Excess

Position error has exceeded maximum value.

F_bd

Bad motor data

Motor profile data is invalid or no motor is selected.

F_EP

EPM failure

EPM failure on power up

-EP-

EPM missing

EPM not recognized (connected) on power up

F_09

Motor over

temperature

Motor over temperature switch activated; Optional motor temperature
sensor (PTC) indicates that the motor windings have reached maximum
temperature

F_10

Subprocessor

failure

Error in data exchange between processors. Usually occurs when EMI
level is high due to poor shielding and grounding.

F_14

Under voltage

Occurs when the bus voltage level drops below 50% of nominal bus
voltage while drive is operating. An attempt to enable the drive with low bus
voltage will also result in this fault

Advertising