Lenze S94P01G Position Servo User Manual

Page 73

Advertising
background image

S94P01G

71

Reference

7.3

Quick Start - External Positioning Mode

Mandatory Signals:
These signals are required in order to achieve motion from the motor.

Connector-Pin

Input Name

Description

P3-1

MA+

Position Reference Input for Master Encoder / Step-Direction Input

P3-2

MA-

Position Reference Input for Master Encoder / Step-Direction Input

P3-3

MB+

Position Reference Input for Master Encoder / Step-Direction Input

P3-4

MB-

Position Reference Input for Master Encoder / Step-Direction Input

P3-26

IN_A_COM

Common Input for Enable Input

P3-29

IN_A3

Enable Input to Controller or switch

Optional Signals:
These signals may be required dependant on the control system being implemented.

Connector - Pin

Input Name

Description

P3-6

+5V

+5V Output for Enable Input (If required)

P3-7

A+

Buffered Encoder Output

P3-8

A-

Buffered Encoder Output

P3-9

B+

Buffered Encoder Output

P3-10

B-

Buffered Encoder Output

P3-11

Z+

Buffered Encoder Output

P3-12

Z-

Buffered Encoder Output

P3-22

ACOM

Analog Common Reference from Controller

P3-23

AO

Analog Output

P3-27

IN_A1

Positive Limit Switch: Required if Limit Switch Function is used

P3-28

IN_A2

Negative Limit Switch: Required if Limit Switch Function is used

P3-41

RDY+

Ready output Collector

P3-42

RDY-

Ready output Emitter

P3-43

OUT1-C

Programmable output #1 Collector

P3-44

OUT1-E

Programmable output #1 Emitter

P3-45

OUT2-C

Programmable output #2 Collector

P3-46

OUT2-E

Programmable output #1 Emitter

P3-47

OUT3-C

Programmable output #3 Collector

P3-48

OUT3-E

Programmable output #1 Emitter

P3-49

OUT4-C

Programmable output #4 Collector

P3-50

OUT4-E

Programmable output #1 Emitter

Advertising