Parameters – Lenze S94P01G Position Servo User Manual

Page 48

Advertising
background image

S94P01G

46

Parameters

5.4.1.1 Manually Obtain the PositionServo Drive’s IP Address

The PositionServo drive can be connected to a local PC or a private network if setting
DHCP=0. In this mode, make sure to set DHCP = 0 via the diagnostic display LED,
refer to section 7.1 for details. One can also verify the IP address of the drive via the
display LED. When shipped from the factory the default IP address of the PositionServo
drive is 192.168.124.120. Before MotionView can establish communications to the
drive, both the PC and the PositionServo drive must be on the same subnet, but have
different addresses. That is, both the PC and PositionServo drive shall have the same
sub-octects IP_1, IP_2 and IP_3 and different IP_4. When connecting MotionView to a
brand-new PositionServo drive out of box, set the PC’s IP address as 192.168.124.1.
Refer to section 6.4.1.3 on how to set up your PC IP address. Every time dHCP, or any
IP sub-octect IP_x is changed, one must reboot the PositionServo drive so that the
change can take effect.

Once the MotionView software is connected to the PositionServo drive, one can change
the DHCP setting and the drive IP address via the communication option “Ethernet” –
“IP setup” in MotionView. If one wants to configure the PositionServo drive’s IP address
under a specific subnet, for example, 10.135.110.xxx as shown below. One can pick
an available IP_4, e.g., 246 is used below, then click “OK” to confirm. After this change,
make sure to reboot the drive. After the drive reboot, the IP address stored in the EPM
before last power-off will be the drive’s IP address. In the meantime, one needs to
configure the PC’s IP address under the same subnet. In case, one may choose “Obtain
an IP Address Automatically” for the PC or pick up an available IP address, refer to
section 5.4.1.3 for details.

5.4.1.2 Automatically Obtain the PositionServo’s IP Address

To use this mode set dHCP = 1 via the diagnostic display LED (refer to section 7.1 for
details). After setting this parameter, cycle the input power to the PositionServo drive
so that the setting can take effect. The LED display will be “----“ if one checks the IP
address octets IP_1, IP_2, IP_3 and IP_4. This means that the drive is still trying to
acquire an IP address from the dHCP server. To obtain the PositionServo drive’s IP
address automatically, there must be a dHCP server available.

5.4.1.3 Set the PC’s IP Address

Follow these steps to set up the PC’s IP address:

To display the IP address of your PC, from the Start menu, select “Control Panel” and
then select “Network Connections”.

Advertising