Technical data 2, 2 scf model designation code, 3 scf specifications – Lenze SCF frequency inverter User Manual

Page 11

Advertising
background image

Lenze 13466146 EDBSF01 v24 EN

11

Technical Data

2

2.2

SCF Model Designation Code

The SCF model number gives a full description of the basic drive unit (see example below).

EXAMPLE: SF210Y (SCF Series, 208/240 Vac, 1 HP, single or three phase input)

SF

2 10 Y

Series:
SF

=

SCF Series Variable Speed AC Motor Drive

Input Voltage:
2

=

208/240 Vac (For 208, 230, and 240 Vac; 50 or 60 Hz)

4

=

400/480 Vac (For 380, 415, 440, 460 and 480 Vac; 50 or 60 Hz)

5

=

480/590 Vac (For 440, 460, 480, 575 and 600 Vac; 50 or 60 Hz)

Rating:
03

=

¼ HP (0.20 kW)

30

= 3 HP (2.2 kW)

200

= 20 HP (15 kW)

05

=

½ HP (0.37 kW)

50

= 5 HP (4.0 kW)

250

= 25 HP (18.5 kW)

10

=

1 HP (0.75 kW)

75

= 7½ HP (5.5 kW)

300

= 30 HP (22 kW)

15

=

1½ HP (1.1 kW)

100

= 10 HP (7.5 kW)

20

=

2 HP (1.5 kW)

150

= 15 HP (11 kW)

Input Phase:
Y

=

Single or three phase input.

No character indicates three phase input only

Mounting Style:
F

=

Through-hole mount with special heatsink

F1

=

Through-hole mount without heatsink (customer supplies heatsink)

No character indicates panel or DIN rail mounting

Application Specific Options:
P

=

PI (setpoint control) software

V

=

High Frequency Output - up to 1000 Hz

2.3

SCF Specifications

Storage Temperature

-20° to 70° C

Ambient Operating Temperature

0° to 50° C (derate 2.5% per °C above 50°)

Ambient Humidity

< 95% (non-condensing)

Maximum Altitude

3300 ft (1000 m) above sea level (derate 5% per additional 3300 ft)

Input Line Voltages

208/240 Vac, 400/480 Vac, 480/590 Vac

Input Voltage Tolerance

+10%, -15%

Input Frequency Tolerance

48 to 62 Hz

Output Wave Form

Sine Coded PWM

Output Frequency

0 - 240 Hz (consult factory for higher output frequencies)

Carrier Frequency

4 kHz to 10 kHz (over 6 kHz requires derating; see parameter P02)

Service Factor

1.00 (up to 6 kHz carrier; derate above 6 kHz; see parameter P02)

Efficiency

Up to 98%

Power Factor (displacement)

0.96 or better

Overload Current Capacity

150% for 60 seconds, 180% for 30 seconds

Speed Reference Follower

0-10 VDC, 4-20 mA

Control Voltage

15 VDC

Power Supply for Auxiliary Relays

50 mA at 12 VDC

Analog Output

0 - 10 VDC or 2 - 10 VDC: Proportional to frequency and load

Digital Outputs

Open-collector outputs: 50 mA at 30 VDC

Advertising