4 Commissioning

Use the

p

and

q

buttons to scroll to the password value (the factory default password is “225”) and

press the Mode button. Once the correct password value is entered, the display will read "P01", which
indicates that the PROGRAM mode has been accessed at the beginning of the parameter menu (P01
is the first parameter). This is shown below:

Press Mode to enter password

Use

p

and

q

to scroll to the password value

Parameter menu is accessed at the first
parameter

NOTE
If the display flashes “Er”, the password was incorrect, and the process to enter the
password must be repeated.

Use the

p

and

q

buttons to scroll to the desired parameter number. In the example below, Parameter

19 is being displayed, which is the ACCELERATION TIME of the drive:

Use

p

and

q

to scroll to the desired

parameter number (the example is
Parameter 19 - ACCELERATION TIME)

Once the desired parameter number is found, press the Mode button to display the present parameter
setting. The upper right-hand decimal point will begin blinking, indicating that the present parameter
setting is being displayed, and that it can be changed by using the

p

and

q

buttons.

Press Mode to display present parameter
setting (example setting is 20.0)

Upper right decimal point blinks

Use

p

and

q

to change setting (example

setting changed to 30.0)

Press Mode to store new setting