2technical data, 2 scl/scm model designation code, 3 scl/scm specifications – Lenze SL User Manual

Page 10

Advertising
background image

10

Lenze 13466147 EDBSM01 v19 EN

2

Technical Data

2.2

SCL/SCM Model Designation Code

The SCL/SCM model number gives a full description of the basic drive unit.

EXAMPLE: SL210S = SCL Series, 208/240 Vac, 1 HP, single phase input

SL

2

10

S

Series:

SL = SCL Series Variable Speed AC Motor Drive with integral line filter

SM = SCM Series Variable Speed AC Motor Drive

Input Voltage:

0 = 120 Vac (For 110, 115, and 120 Vac; 50 or 60 Hz)
2 = 208/240 Vac (For 208, 220, 230, and 240 Vac; 50 or 60 Hz)
4 = 400/480 Vac (For 380, 415, 460, and 480 Vac; 50 or 60 Hz)

Rating:

4 = 0.33 Hp (0.25 kW)

15 = 1.5 Hp (1.1 kW)

75 = 7.5 Hp (5.5 kW)

5 = 0.50 Hp (0.37 kW)

20 = 2 Hp (1.5 kW)

100 = 10 Hp (7.5 kW)

8 = 0.75 Hp (0.55 kW)

30 = 3 Hp (2.2 kW)

150 = 15 Hp (11 kW)

10 = 1 Hp (0.75 kW)

50 = 5 Hp (4.0 kW)

Input Phase:

S = Single phase input only.

No character indicates three phase input only

2.3

SCL/SCM Specifications

Conformity

CE

Low Voltage Directive (2006/95/EC)

Approvals

UL 508C

Underwriters Laboratories - Power Conversion Equipment

Storage Temperature

-20° to 70° C

Ambient Operating Temperature

0° to 40° C (derate 2.5% per °C above 40°)

Ambient Humidity

< 95% (non-condensing)

Altitude

3300 ft (1000 m) above sea level (derate 5% per additional 3300 ft)

Input Line Voltages

120, 208/240, 400/480 Vac

Input Voltage Tolerance

+10%, -15%

Input Frequency Tolerance

48 to 62 Hz

Output Wave Form

Sine Coded PWM

Output Frequency

0 - 240 Hz

Carrier Frequency

4 kHz to 10 kHz (10 kHz requires derating; see parameter P02)

Service Factor

1.00 (up to 8 kHz carrier; derate for 10 kHz; see parameter P02)

Efficiency

Up to 98%

Power Factor (displacement)

0.96 or better

Overload Current Capacity

150% for 60 seconds, 180% for 30 seconds

Speed Reference Follower

0-10 VDC, 4-20 mA

Digital Outputs

(1) Normally open relay; contacts rated 3 amps at 250 Vac

(1) Digital output (current-sourcing); rated 50 mA at 12 VDC

Earth Leakage Current (EN 50178)

SCL: > 3.5 mA to PE SCM: < 3.5 mA to PE

Advertising