Installation 3 – Lenze SL User Manual

Page 21

Advertising
background image

Lenze 13466147 EDBSM01 v19 EN

21

Installation 3

3.6

SCL/SCM Control Wiring Diagrams

3.6.1 SCL/SCM Terminal Strip

Shown below is the control terminal strip, along with a brief description of the function of each
terminal. The following wiring diagram examples provide a quick reference to wire the drive for the
most common configurations.

Maintained

RUN/STOP

Contact

1

2

25

13A

13E

13B

RUN

5

6

11

16

17

SIGNAL COMMON

0-10V DC INPUT

TB-13A FUNCTION SELECT

TB-13B FUNCTION SELECT

TB-13E FUNCTION SELECT

4-20mA INPUT

FORM A RELAY

-

+

+

SPEED POT POWER SUPPLY

DIGITAL INPUT REFERENCE

SCL/SCM Terminal Strip

NOTE
•

The function of terminals TB-13A, 13B, 13E and the Form A relay at terminals 16
and 17 are dependent on the programming of certain parameters.
Refer to Section 4.4 Description of Parameters.

•

The digital inputs (terminals 1, 13A, 13B, and 13E) are active-high. They can
be activated using terminal 11 (which is +12 VDC) as shown in the following
diagrams, or by using an external voltage source with a range of +12 VDC to +28
VDC (+ 10%).