Installation 3 – Lenze SL User Manual

Page 21

Advertising
background image

Lenze 13466147 EDBSM01 v19 EN

21

Installation 3

3.6

SCL/SCM Control Wiring Diagrams

3.6.1 SCL/SCM Terminal Strip

Shown below is the control terminal strip, along with a brief description of the function of each
terminal. The following wiring diagram examples provide a quick reference to wire the drive for the
most common configurations.

Maintained

RUN/STOP

Contact

1

2

25

13A

13E

13B

RUN

5

6

11

16

17

SIGNAL COMMON

0-10V DC INPUT

TB-13A FUNCTION SELECT

TB-13B FUNCTION SELECT

TB-13E FUNCTION SELECT

4-20mA INPUT

FORM A RELAY

-

+

+

SPEED POT POWER SUPPLY

DIGITAL INPUT REFERENCE

SCL/SCM Terminal Strip

NOTE

The function of terminals TB-13A, 13B, 13E and the Form A relay at terminals 16
and 17 are dependent on the programming of certain parameters.
Refer to Section 4.4 Description of Parameters.

The digital inputs (terminals 1, 13A, 13B, and 13E) are active-high. They can
be activated using terminal 11 (which is +12 VDC) as shown in the following
diagrams, or by using an external voltage source with a range of +12 VDC to +28
VDC (+ 10%).

Advertising