Commissioning 4

P55

0-10 VDC INPUT

Parameter P55 displays the level of the 0-10 VDC input signal at TB-5. A reading of 100% indicates
a 10 VDC input at TB-5.

P56

4-20 mA INPUT

Parameter P56 displays the level of the 4-20 mA input signal at TB-25. A reading of 20% indicates a
4 mA input at TB-25, and a reading of 100% indicates a 20 mA input at TB-25.

P57

TERMINAL STRIP STATUS

P57 indicates the status of several terminals using the vertical segments of the LED display. An
illuminated segment indicates that the particular terminal is closed to TB-11.

FACTORY
RESERVED

TB-1

TB-13A

TB-13B

TB-13E
(output)

TB-13E
(input)

P58

KEYPAD AND PROTECTION STATUS

P58 indicates the status of the buttons on the keypad, and the status of the protective circuitry
in the drive, using the horizontal segments of the LED. An illuminated segment indicates that the
corresponding button is pressed, or the protective circuit is active.

FCLIM

Mode

OUTPUT

FAULT

p

q

FCLIM is an abbreviation for Fast Current Limit.