Electrical installation

Power terminals
Connection to the DC bus (+U

G

, −U

G

)

5

l

106

EDKCSDX064 DE/EN/FR 3.0

5.2.1

Connection to the DC bus (+U

G

, −U

G

)

(

Stop!

No device protection for DC bus voltage surges

In passive axis modules (without 24 V−supply), the charging circuit
can be overloaded through DC bus voltage surges.

Possible consequences:

ƒ

Destruction of the device

Protective measures:

ƒ

All axis modules in the DC−bus connection should be basically
supplied with a control voltage of 24 V.

ƒ

If the total cable length is > 20 m, install an axis module or a capacitor
module directly at the power supply module.

ƒ

Design the ±U

G

cables twisted and as short as possible. Ensure

short−circuit−proof routing!

ƒ

Cable length (module

« module) > 30 cm: install shielded ±U

G

cables.

,

Documentation of the ECSxE power supply module

Observe the enclosed notes.

,

Documentation of the ECSxK capacitor module

Observe the enclosed notes.