Safety instructions

Thermal motor monitoring
Self−ventilated motors

2

l

86

EDKCSDX064 DE/EN/FR 3.0

Effect of code C0129/x

0

0.9

0

0.1

C0129/2

0.2

0.3

0.4

0.6

0.7

0.8

1.0

1.1

1

0

0.132

2

I

/ IN

n

/ nN

C0129/1

3

9300STD350

Fig. 2−2

Working point in the range of characteristic lowering

The lowered speed / torque characteristic (Fig. 2−2) reduces the permissible
thermal load of self−ventilated standard motors. The characteristic is a line the
definition of which requires two points:

ƒ

Point

0: Definition with C0129/1

This value also enables an increase of the maximally permissible load.

ƒ

Point

1: Definition with C0129/2

With increasing speeds, the maximally permissible load remains
unchanged (I

Mot

= I

rated

).

In Fig. 2−2, the motor speed and the corresponding permissible motor torque (

3)

can be read for each working point (

2on the characteristic (0) ... 1). 3 can also

be calculated using the values in C0129/1and C0129/2 (evaluation
coefficient "y",

87).