Electrical installation, Stop – Lenze ECSDAxxx User Manual

Page 119

Advertising
background image

Electrical installation

Control terminals

Analog input

5

l

119

EDKCSDX064 DE/EN/FR 3.0

Analog input configuration

ƒ

Use C0034 to set whether the input is to be used for a master voltage
(

±10 V) or a master current (+4 ... 20 mA or ±20 mA).

ƒ

Set jumper bar X3 according to the setting in C0034:

(

Stop!

Do not plug the jumper on the pins 3−4! The axis module cannot be
initialised like this.

Jumper bar X3

Setting

Measuring range

6

4

2

5

3

1

5−6 open

Jumper on 1−2: Parking

position

C0034 = 0 (master voltage)

l

Level: −10 ... +10 V

l

Resolution: 5 mV (11 bits + sign)

l

Scaling:

±10 V º ±16384 º ±100 %

6

4

2

5

3

1

5−6 closed

C0034 = 1 (master current)

l

Level: +4 ... +20 mA

l

Resolution: 20

mA (10 bits without

sign)

l

Scaling:
+4 mA º 0 º 0 %

+20 mA º 16384 º 100 %

C0034 = 2 (master current)

l

Level: −20 ... +20 mA

l

Resolution: 20

mA (10 bits + sign)

l

Scaling:

±20 mA º ±16384 º ±100 %

Advertising
This manual is related to the following products: