background image

Electrical installation

Power terminals
Motor connection

5

l

110

EDKCSDX064 DE/EN/FR 3.0

5.2.2

Motor connection

ECSXA010

Fig. 5−3

Motor and motor holding brake connection

Motor cables

ƒ

Use low−capacitance motor cables. Capacitance per unit length:

Core/core: max. 75 pF/m

Core/shield: max. 150 pF/m

ƒ

Length: max. 50 m, shielded

ƒ

The cross−section of the motor cables are selected according to the motor
standstill current (I

0

) when using synchronous motors or according to the

rated motor current (I

N

) for asynchronous motors.

ƒ

Length of the unshielded ends: 40 ... 100 mm (depending on the cable
cross−section)

ƒ

Lenze system cables meet these requirements.

ƒ

Use the ECSZS000X0B shield mounting kit for EMC−compliant wiring.

,

Mounting instructions for ECSZS000X0B shield mounting

Here you can find more information on wiring according to EMC.