Mechanical installation

Mounting with thermal separation (push−through technique)
Dimensions

4

l

98

EDKCSDX064 DE/EN/FR 3.0

Dimensions of mounting cutout

)

Note!

Installation with shield mounting ECSZS000X0B:

ƒ

Clearance below the mounting cutout > 220 mm

³

70

mm

³

90

mm

a1

a1

1

0

c1

h

c1

g

g

b1

b1

d

2

ECSXA063

Fig. 4−2

Dimensions of mounting cutout

0

Mounting surface

1

Mounting cutout for size

0

2

Mounting cutout for size

1

Axis module

Dimensions [mm]

Type

Size

a1

b1

c1

d

g

h

ECSD

L004

0

78.5

197

75

250

M5

10.5

ECSD

L008

ECSD

L016

ECSD

L032

ECSD

L048

1

121.5

ECSD

L064