General data/operating conditions

3

15

EDBCSXKXXX EN 1.0

3

Technical data

3.1

General data/operating conditions

Standards and operating conditions
Conformity

CE

Low-Voltage Directive (73/23/EWG)

Approvals

UL 508C

Power Conversion Equipment

Underwriter Laboratories (File No. E132659)

for USA and Canada

Vibration resistance

Accelerational stability up to 0.7 g (Germanischer Lloyd, general conditions)

Climatic conditions

Class 3K3 to EN 50178 (without condensation, relative humidity 30 ... 95 %)

Degree of pollution

VDE 0110 part 2 pollution degree 2

Packaging (DIN 4180)

Delivery packing

Permissible

Transport

-25 ... +70 °C

temperature range

Storage

-25 ... +55 °C

Operation

0 ... +55 °C

reduce the rated AC current by 2 %/°C above +40°C

Permissible installation height

0 ... 4000 m amsl

reduce rated AC current by 5%/1000 m above 1000 m amsl

Installation

Installation into control cabinet

Mounting position

Vertically suspended

Free space

Above/below

50 mm

p

To the sides

Side-by-side mounting without any clearance

General electrical data
EMC

Compliance with EN 61800-3

Noise emission

Compliance with limit value class A to EN 55011

(achieved with application-specific collective filter)

Noise immunity

Requirements to EN 61800-3

y

Requirements

Standard

Severity

ESD

1)

EN 61000-4-2

3, i. e.

z

8 kV with air discharge

z

6 kV with contact discharge

High frequency in cables

EN 61000-4-6

10 V; 0.15 ... 80 MHz

RF interference (enclosure)

EN 61000-4-3

3, i. e. 10 V/m;

80 ... 1000 MHz

Burst

EN 61000-4-4

3/4, i. e. 2 kV/5 kHz

Surge (on mains cable)

EN 61000-4-5

3, i. e. 1.2/50 µs

z

1 kV phase-phase

z

2 kV phase PE

Insulation resistance

Overvoltage category III to VDE 0110

Discharge current against PE (to EN 50178)

> 3.5 mA AC for operation with corresponding controllers

Enclosure

z

IP20 for standard mounting

z

IP20 for mounting in cold-plate technique

z

IP20 for mounting in push-through technique; IP54 on the heatsink side

Protective insulation of control circuits

Safe disconnection from supply: Double/reinforced insulation to EN 50178;

Rated insulation voltage 300 V x √2

1)

Noise immunity in the above-mentioned severities must be guaranteed through the control cabinet! The user must

check the compliance with the severities!