Mechanical installation

Thermally separated mounting (”push-through technique”)

4

20

EDBCSXKXXX EN 1.0

Dimensions of mounting cutout

³

60

mm

³

90

mm

a1

a1

b1

b1

1

2

0

c1

h

d

c1

g

g

ECSXK063

Fig.4-3

Dimensions of mounting cutout for thermally separated mounting, ECSDKxxx type

Mounting plate

Mounting cutout for ECSDK001

Mounting cutout for ECSDK002

Capacitor modules

Dimensions [mm]

Type

Size

A1

b1

c1

D

g

h

ECSDK001

1

78.5

197

75

250

M5

10 5

ECSDK002

2

121.5

197

75

250

M5

10.5

Mounting

Stop!

When boring through the rear panel of the control cabinet:

Seal the fixing screws with a liquid thread seal to ensure the protection

class IP54 for the separated heatsink.

For mounting the capacitor module ECSDKxxx proceed as follows:
1. Prepare fixing holes for the clips (see drawing).
2. Prepare mounting cutout.
3. Fix the clips.
4. Push the capacitor module into the mounting cutout.
5. Let the capacitor module snap into place at the top and bottom.