4.8 Ethernet Parameters
Drive variables #67-70 are Ethernet communication programming parameters specifically for configuration of
the ethernet interface.
Table 6: Ethernet Variables - Excerpted from PS Variable List
PID
Variable Name
Type Format EPM Access Description
Units
67
VAR_IP_ADDRESS
W
Y
R/W
Ethernet IP address. IP address changes at
next boot up. 32 bit value
68
VAR_IP_MASK
W
Y
R/W
Ethernet IP NetMask. Mask changes at next
boot up. 32 bit value
69
VAR_IP_GATEWAY
W
Y
R/W
Ethernet Gateway IP address. Address
changes at next boot up. 32 bit value
70
VAR_IP_DHCP
W
Y
R/W
Use DHCP: 0, 1
0 - manual;
1 - use DHCP service
4.9 Negative Number Transmission
Drive variables 51, 60, 79, 81 and 90 are signed integer values and could be negative. These registers are sent
over the modbus communications in signed internal units.
Table 7: Signed Integer Variables - Excerpted from PS Variable List
PID
Variable Name
Type Format EPM Access Description
Units
51
VAR_VREG_WINDOW
vel
W
Y
R/W
Gains scaling coefficient
Range: -16 to +4
60
VAR_VLIMIT_ATSPEED
F
Y
R/W
Target Velocity for At Speed window
Range: -10000 - +10000
Rpm
79
VAR_M2SRATIO_MASTER
W
Y
R/W
Master to system ratio.
Master counts range: -32767 - +32767
Value will be applied upon write to PID #80.
Write to this PID followed by writing to
PID#80 to apply new ratio pair
81
VAR_S2PRATIO_SECOND
W
Y
R/W
Secondary encoder to prime encoder ratio.
Second counts range: -32767 - +32767
Value will be applied upon write to PID #82.
Write to this PID followed by writing to
PID#82 to apply new ratio pair
90
VAR_AIN1_OFFSET
Y
R/W
Analog input #1 offset. Applied when used
as current/velocity reference
Range: -10,000 to +10,000
mV