Reference – Lenze E94P PositionServo Modbus User Manual

Page 32

Advertising
background image

32

P94MOD01C

Reference

Index

Name

Type

Format

EPM

Access

Description

Range

Unit

RAM

Registers

32bit

Integer
Access

4X

Register #

RAM

Register

32bit
Float

Access

4X

Register #

EPM

Reg Copy

32bit

Integer
Access

4X

Register #

EPM

Reg Copy

32bit
Float

Access

4X

Register #

RAM

Register

16bit

Signed

Integer

4X

Register #

EPM

INT16

4X

Register #

66

VAR_OUTPUT

W

N

R/W

Digital outputs states. Writing to this
variables sets/resets digital outputs except
outputs which have been assigned special
function.
Output 1 Bit 0
Output 2 Bit 1
Output 3 Bit 2
Output 4 Bit 3

Output 1 -
Output 4

133

645

1157

1669

2115

2371

67

VAR_IP_ADDRESS

W

Y

R/W

Ethernet IP address. IP address changes at
next boot up. 32 bit value

135

647

1159

1671

2116

2372

68

VAR_IP_MASK

W

Y

R/W

Ethernet IP NetMask. Mask changes at next
boot up. 32 bit value

137

649

1161

1673

2117

2373

69

VAR_IP_GATEWAY

W

Y

R/W

Ethernet Gateway IP address. Address
changes at next boot up. 32 bit value

139

651

1163

1675

2118

2374

70

VAR_IP_DHCP

W

Y

R/W

Use DHCP
0 - manual; 1 - use DHCP service

0 - 1

141

653

1165

1677

2119

2375

71

VAR_AIN1

F

N

R

Analog Input AIN1 current value

[V]olt

143

655

1167

1679

2120

2376

72

VAR_AIN2

F

N

R

Analog Input AIN2 current value

[V]olt

145

657

1169

1681

2121

2377

73

VAR_BUSVOLTAGE

F

N

R

Bus voltage

[V]olt

147

659

1171

1683

2122

2378

74

VAR_HTEMP

F

N

R

Heatsink temperature
0 - for temperatures < 40C and actual heat
sink temperature for temperatures >40 C

0 - actual
heat sink
temperature

[c]

149

661

1173

1685

2123

2379

75

VAR_ENABLE_
ACCELDECEL

vel

Y

R/W

Enable Accel/Decel function for velocity
mode
0 - disable; 1 - enable

0 - 1

151

663

1175

1687

2124

2380

76

VAR_ACCEL_LIMIT

vel

F

Y

R/W

Accel value for velocity mode

0.1 -
5000000

Rpm*Sec

153

665

1177

1689

2125

2381

77

VAR_DECEL_LIMIT

vel

F

Y

R/W

Decel value for velocity mode

0.1 -
5000000

Rpm*Sec

155

667

1179

1691

2126

2382

78

VAR_FAULT_RESET

W

Y

R/W

Reset fault configuration
0 - on activation of Enable/Inhibit input (A3)
1 - on deactivation of Enable/Inhibit input
(A3)

0 - 1

157

669

1181

1693

2127

2383

79

VAR_M2SRATIO_MASTER

W

Y

R/W

Master to system ratio
Master counts range: -32767 - +32767

-32767 -
+32767

159

671

1183

1695

2128

2384

80

VAR_M2SRATIO_SYSTEM

W

Y

R/W

Master to system ratio
System counts range: 1 - 32767

1 - 32767

161

673

1185

1697

2129

2385

81

VAR_S2PRATIO_SECOND

W

Y

R/W

Secondary encoder to prime encoder ratio
Second counts range: -32767 - +32767

-32767 -
+32767

163

675

1187

1699

2130

2386

82

VAR_S2PRATIO_PRIME

W

Y

R/W

Secondary encoder to prime encoder ratio
Prime counts range: 1 - 32767

1 - 32767

165

677

1189

1701

2131

2387

83

VAR_EXSTATUS

W

N

R

Extended status. Lower word copy of DSP
status flags.

167

679

1191

1703

2132

2388

84

VAR_HLS_MODE

W

Y

R/W

Hardware limit switches
0 - not used; 1 - stop and fault; 2 - fault

0 - 2

169

681

1193

1705

2133

2389

85

VAR_AOUT_FUNCTION

W

Y

R/W

Analog output function range: 0 - 8
0 - Not assigned
1 - Phase Current (RMS)
2 - Phase Current (Peak Value)
3 - Motor Velocity
4 - Phase Current R
5 - Phase Current S
6 - Phase Current T
7 - Iq current
8 - Id current

0 - 8

171

683

1195

1707

2134

2390

86

VAR_AOUT_VELSCALE

F

Y

R/W

Analog output scale for velocity quantities.

0 - 10

mV/Rpm

173

685

1197

1709

2135

2391

87

VAR_AOUT_CURSCALE

F

Y

R/W

Analog output scale for current related
quantities.

0 - 10

V/A

175

687

1199

1711

2136

2392

88

VAR_AOUT

F

N

W

Analog output value.(Used if VAR #85 is
set to 0)

0 - 10

V

177

689

1201

1713

2137

2393

89

VAR_AIN1_DEADBAND

F

Y

R/W

Analog input #1 dead-band. Applied when
used as current or velocity reference.

0 - 100

mV

179

691

1203

1715

2138

2394

90

VAR_AIN1_OFFSET

Y

R/W

Analog input #1 offset. Applied when used as
current/velocity reference

-10,000 to
+10,000

mV

181

693

1205

1717

2139

2395