Reference – Lenze E94P PositionServo Modbus User Manual

Page 37

Advertising
background image

37

P94MOD01C

Reference

Index

Name

Type

Format

EPM

Access

Description

Range

Unit

RAM

Registers

32bit

Integer
Access

4X

Register #

RAM

Register

32bit
Float

Access

4X

Register #

EPM

Reg Copy

32bit

Integer
Access

4X

Register #

EPM

Reg Copy

32bit
Float

Access

4X

Register #

RAM

Register

16bit

Signed

Integer

4X

Register #

EPM

INT16

4X

Register #

234

VAR_CAN_BAUD_EPM

W

Y

R/W

CAN Bus Parameter: Baud Rate: 1 - 8
1 - 10k; 2 - 20k; 3 - 50k; 4 - 125k
5 - 250k; 6 - 500k; 7 - 800k; 8 - 1000k

1 - 8

469

981

1493

2005

2283

2539

235

VAR_CAN_ADDR_EPM

W

Y

R/W

CAN Bus Parameter: Address

1-127

471

983

1495

2007

2284

2540

236

VAR_CAN_OPERMODE_
EPM

W

Y

R/W

CAN Bus Parameter: Boot-up Mode
(Operational State Control)
0 - enters into pre-operational state
1 - enters into operational state
2 - pseudo NMT: sends NMT Start Node
command after delay (set by variable 237)

0 - 2

473

985

1497

2009

2285

2541

237

VAR_CAN_OPERDELAY_
EPM

W

Y

R/W

CAN Bus Parameter: pseudo NMT mode
delay time in seconds

Refer to
variable 236

sec

475

987

1499

2011

2286

2542

238

VAR_CAN_ENABLE_EPM

W

Y

R/W

CAN Bus Parameter: Mode Control
0 - Disable CAN interface
1 - Enable CAN interface in DS301 mode
2 - Enable CAN interface in DS402 mode
3 - Enable DeviceNet
4 - Enable PROFIBUS DP

0 - 4

477

989

1501

2013

2287

2543

239

VAR_HOME_ACCEL

F

Y

R/W

Homing Mode: ACCEL rate

0 -
10000000.0

UU/sec2

479

991

1503

2015

2288

2544

240

VAR_HOME_OFFSET

F

Y

R/W

Homing Mode: Home Position Offset

-32767 to
+32767

UU

481

993

1505

2017

2289

2545

241

VAR_HOME_OFFSET_
PULSES

W

Y

R/W

Homing Mode: Home Position Offset in
encoder counts

+/-
2147418112

EC

483

995

1507

2019

2290

2546

242

VAR_HOME_FAST_VEL

F

Y

R/W

Homing Mode: Fast Velocity

-10000 to
+10000

UU/sec

485

997

1509

2021

2291

2547

243

VAR_HOME_SLOW_VEL

F

Y

R/W

Homing Mode: Slow Velocity

-10000 to
+10000

UU/sec

487

999

1511

2023

2292

2548

244

VAR_HOME_METHOD

W

Y

R/W

Homing Mode: Homing Method

1 - 35

489

1001

1513

2025

2293

2549

245

VAR_START_HOMING

W

N

W

Homing Mode: Start Homing
0 - No action; 1 - Start Homing

0 - 1

491

1003

1515

2027

2294

2550

246

VAR_HOME_SWITCH_
INPUT

W

Y

R/W

Homing Mode: Switch Input Assignment:
0-3: A1-A4
4-7: B1-B4
8-11: C1-C4

0-11

493

1005

1517

2029

2295

2551

247

VAR_M_VALIDATE_
MOTOR

W

N

W

Makes Drive accept Motor’s parameters
0 - No action
1 - Validate Motor Data

0 -1

495

1007

1519

2031

2296

2552

248

VAR_M_I2T

F

Y

R/W

Motor

497

1009

1521

2033

2297

2553

249

VAR_M_EABSOLUTE

F

Y

R/W

Motor

499

1011

1523

2035

2298

2554

250

VAR_M_ABSWAP

F

Y

R/W

Motor Encoder Feedback: B leads A
0 - No Action
1 - B leads A for forward checked (active)

0 - 1

501

1013

1525

2037

2299

2555

251

VAR_M_HALLS_INVERTED

F

Y

R/W

Motor Encoder Feedback: Halls
0 - No Action
1 - Inverted Halls Box checked (active)

0 - 1

503

1015

1527

2039

2300

2556

252

RESERVED

Do NOT use

505

1017

1529

2041

2301

2557

253

RESERVED

Do NOT use

507

1019

1531

2043

2302

2558

254

RESERVED

Do NOT use

509

1021

1533

2045

2303

2559

255

RESERVED

Do NOT use

511

1023

1535

2047

2304

2560

256

RESERVED

Do NOT use

513

1025

1537

2049

2305

2561

This is a condensed PID List to show the corresponding Modbus 4X Registers for PIDs 1-256. Modbus RTU
can not access beyond PID256. For the complete variable list refer to the PositionServo Programming Manual
(PM94P01 or PM94M01).